PowMr 5500w Hybrid Inverter with 80A MPPT Charge Controller 48V DC to 220/230V AC, Off-Grid Pure Sine Wave Inverter Support Running Without Battery, Suitable for 48v Lead-Acid and Lithium Batteries

Write a review
$719.00
Free shipping
POW-HVM5.5K-48V
In stock
+
PowMr INVERTER

PowMr 5500W Solar Inverter 48V DC to 220V-230V AC + 80A MPPT Charge Controller

This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

Features

 

  • Pure sine wave inverter
  • Inverter running without battery
  • Built-in MPPT solar controller
  • Configurable input voltage range for home appliances and personal computers via LCD setting
  • Configurable battery charging current based on applications via LCD setting
  • Configurable AC/Solar Charger priority via LCD setting
  • Compatible to mains voltage or generator power
  • Auto restart while AC is recovering
  • Overload/ Over temperature/ short circuit protection
  • Smart battery charger design for optimized battery performance
  • Cold start function

 

FOUR CHARGING&THREE OUTPUT MODES

4modes&3modes

PV Module Selection

PV Selection

Operation and Display Panel

Specifications

INVERTER MODEL 5.5KVA
Rated Power 5500W
Max. PV Open CircuitVoltage 500Vdc
PV Array MPPT Voltage Range 120Vdc~450Vdc
Max. Input Current 18A
AC Charging Current (Max) 80Amp
Nominal Input Voltag 230Vac
Output Voltage Regulation 230Vac±5%
Frequency 60Hz or 50Hz
Operating temperature range -10°C to 55°C

Systems Digram

Systems Digram

NOTE:

 

  1. Do not mount the inverter on flammable construction materials.
  2. Before using this inverter, please read all instructions and caution marks on the unit, understand the batteryies and all sppropriate sections of its user manual.
  3. All wiring must be performed by a qualified personnel
  4. Do not disassemble the unit.
  5. Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
  6. Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuited when these inverters are worked in parallel operation.

 

This PowMr off grid solar inverter all-in-one does not support parallel operation, and does not support phase separation!

(Single phase 220V AC /A Output, NOT Support 110V !!! )